DataCenter RackMatic manual sliding door (MP11-0002)
DataCenter RackMatic manual sliding door (MP11-0002)
7 720,92 zł / jdn
Zadzwoń
Prośba o więcej informacji
Dodaj do ulubionych

DataCenter RackMatic manual sliding door (MP11-0002)

  • Czas dostawy:4 dni
7 720,92 zł /jednostka
Opis produktu

DataCenter RackMatic manual sliding door (MP11-0002)

:
RackMatic compound DataCenter rack modular cabinets 19 \"42U A modular RackMatic DataCenter consists of the following parts:


Couples rack cabinets 19 \"42U. every 19\" rack having a size of 800x1000mm (width x depth). The cabinets are supplied in pairs. Each pair of cabinets is connected by the corridor ceiling. The cabinets are joined laterally with the following, creating a DataCenter with a central corridor. Lockers are references # and # MP02 MP01. </ Li>
Gateway to the DataCenter. It is the gateway to the central hall DataCenter. It is a sliding door that can be manual (part # MP11) or automatic/motorized (item # MP12). Using the door is optional and is only required to block access to the datacenter. If one of the openings DataCenter lobby is against a wall, just need a door. If the DataCenter has the hall open at both ends, 2 doors needed. </ Li>
</ Ul>
Differences # MP01 and MP02 # </ b>



Both references are a pair of 19 \"rack cabinet, 42U height and base size 800x1000mm. Difference is in the side seam with the next pair of fitted or sliding door. Depending on the location of the cabinet in the DataCenter, should . acquire # # MP01 or MP02 The criteria are:


# MP01: The pair of cabinets that goes to the ends of DataCenter. One side of the pair of cabinets are ready to fix the rail sliding door, in case you want to install sliding door. The other part of the pair of cabinets ready to be attached to another pair of cabinets. In addition, the side which corresponds to the outside of the DataCenter, has side covers, closing the DataCenter. </ Li>
# MP02: The pair of cabinets that goes in the middle or the DataCenter. This pair of cabinets is ready to join another couple of cabinets on both sides. </ Li>
</ Ul>
Examples of configurations </ b>


DataCenter 4-shelf rack 19 \"(2 couples) and 2 manual doors at both ends. 2 # 2 # MP01 and MP11 </ li>
DataCenter 4-shelf rack 19 \"(2 couples) and 1 manual door at one end: 2 # 1 # MP01 and MP11 </ li>.
DataCenter 4-shelf rack 19 \"(2 couples) without doors: 2 # MP01 </ li>.
6 DataCenter rack cabinets 19 \"(3 couples) and 2 manual doors at both ends: 2 # MP01, MP02 and 1 # 2 # MP11 </ li>.
8 DataCenter rack cabinets 19 \"(4 couples) and 2 automatic doors at both ends: 2 # MP01, MP02 and 2 # 2 # MP12 </ li>.
10 DataCenter rack cabinets 19 \"(5 couples) and 2 automatic doors at both ends: MP01 2 #, 3 # 2 # MP02 and MP12 </ li>.
12 DataCenter rack cabinets 19 \"(6 pairs), 1 automatic door at one end and 1 manual door at the other end of the hall. 2 # MP01, MP02 4 # 1 # 1 # MP12 and MP11 </ li>
14 DataCenter rack cabinets 19 \"(7 couples) without end doors of the hall: 2 # 5 # MP01 and MP02 </ li>.
</ Ul>
DataCenter Specifications </ b>


DataCenter compound 19 \"rack cabinets, base 42U 800x1000mm (width x depth). </ li>
rack Compatible with standard 19 \"ESTI. </ li>
In the back of the cabinet features perforated metal gate (grid) double sheet. The back of the cabinet is the outside of the DataCenter. This door has a lock. </ Li>
In the front of the cabinet does not have any doors. The front of the cabinet is accessed from the central hallway inside the DataCenter. No door is required to facilitate access and because there is the option to install the sliding door to block access to all the DataCenter. </ Li>
couple closets bind frontally through the hallway ceiling. Corridor width (roof) is 1200mm. The roof of the hall is supplied with each pair of cabinets. On the roof can run wires between the different cabinets. </ Li>
Each pair of cabinets can be joined with another couple of cabinets (middle or end), it can be left unbound (ends) or you can set a rail sliding door (enter). All accessories are supplied for connecting with another couple of cabinets. </ Li>
Each cabinet has a closed base truck and fixing the cabinet and the cables that can move between different cabinets. The cables are hidden by the floor up. </ Li>
Each cabinet has a board 4 fans on top. The fans are 120x120mm and 220VAC. </ Li>
Vertical Grommets on both sides of the cabinet. The cabinet of 800mm width allows a vertically chute on both sides of each shelf. The cables are hidden in the vertical chute up to the ceiling or floor member to communicate with other neighboring lockers, just DataCenter. </ Li>
</ Ul>
reference MP11 Content </ b>


2 sliding glass doors to display inside the DataCenter. 42U size (height) x 700mm (width). </ Li>
1 Rail for sliding the sliding doors. </ li>
Key lock and handle. </ li>
</ Ul>
(Zobacz więcej)
Słowa klucze: DataCenter RackMatic manual
Nr. identyfikacyjny produktu: 2451046 | Sprzedawca Cablematic
  • Data dodania produktu 08/12/2014
  • -
  • Zmiany wprowadzone przez sprzedawcę. 21/02/2017
(Zobacz więcej)
Zgłoś się po indywidualną wycenę do Dostawca
Dane kontaktowe Zmień dane | Zmień użytkownika
  • Zapomniałem hasła
  • Bez specyfikacji
  • Jestem zainteresowany/a: jednostek
Naciskając przycisk "Prośba o więcej informacji" zgadzasz się na Regulaminu i Polityki ochrony prywatnosci.
Formularz kontaktowy zawiera błędy, proszę sprawdzić wpisane informacje.
Informację o sprzedawcy
Hiszpania
Firma Premium przed 2 latami
Firma zweryfikowana
Zadzwoń na Dostawca
Inne produkty Cablematic
Zareklamuj firmę na
na portalu handlowym dla firm.
Zarejestruj firmę